Errata

Errors within The Guide will be highlighted here.

 

Page 13 - Vox AC30/4 schematic.

There is a missing connection to ground from the junctions of R45, R46 and R48.

Page 21 - Vox AC30/4 layout.

There is a missing connection to ground from the junctions of R45, R46 and R48 on the upper tag strip.

Page 23 - Vox AC30/6 Layout Integral Top Boost

A short link is incorrectly shown between the fuse holder and the switched neutral side of the mains switch.

There should be no link there.

Page 35 - Vox AC15 layout.

There is a missing connection between R59 and the junctions of C38 and C39 on the lower tag strip.

Page 37 - AC15 component layout power supply and output stage.

The diagram shows a link on the mains transformer between 0 volt primary and the HT secondary centre tap.

There should be no link between these two points.

 

 

 

 

 